48 GOSSEN Mueller & Weigert
Moving-Coil Movement with Rectifier, 240° Scale,
Narrow Bezel per DIN 43 718, Dull Black
Front Dimensions 48 x 48 mm 72 x 72 mm 96 x 96 mm 144 x 144 mm
Type V-Pq 48-250 V-Pq 72-250 V-Pq 96-250 Pq 144-250
Scale Length 73 mm 113 mm 151 mm 235 mm
Accuracy Class 1.5 1.5 1.5 1.5
Weight in kg, Approx. 0.16 0.2 0.25 0.65
Nominal Insulation Voltage 660 V 1000 V 1000 V 660 V
Test Voltage 2 kV 3 kV 3 kV 2 kV
Front Housing-Panel Protection IP 52 IP 52 IP 52 IP 52
Fasteners (see next page) leaf spring type S type S type G
Housing Material polycarbonate polycarbonate polycarbonate sheet metal
Interchangeable Scale yes yes yes no
Type V-Pq96-250
Square Panel Meters
for Alternating Current 40 ... 45 ... 65 ... 1000 Hz or
for Alternating Voltage 40 ... 45
... 65 ... 10000 Hz
Technical Data
Description
Analog Panel Meter with Moving-Coil Movement and Rectifier
Reference Conditions
Voltage Drop / Power Consumption
Nominal range Of Use Limits
Dimensions
Display
Scale Graduation Coarse-fine
Pointer Beam pointer with knife-edge
Mechanical Design
Housing Material Polycarbonate, self-extinguishing and drip-proof per UL94V-0
or sheet metal housing (see above).
Sheet metal housing for V-Pq72-250 and V-Pq96-250
available as option
Replaceable Glass faceplate, bezel and scale (no interchangeable scales for
front dimensions 144 x 144 mm)
Terminals M4 screw terminals with self-lifting terminal clips. Screws can
be turned with cross-head or standard screw drivers.
Exception: M3 screw terminals for V-Pq48-250
≥ 100 mA (with attached matching transformer)
Contact Protection Available as option
Reference Quantities Reference Condition
Waveshape sinusoidal, total harmonic distortion ≤ 1%
Frequency 45 ... 65 Hz
Ambient Temperature 23°C ± 2°C
Position of Use control panel vertical ± 1°
Other DIN EN 60051
Voltage Drop For Measuring Ranges < 100 mA: approx. 1.2 V
Power Consumption For Measuring Ranges ≥ 100 mA: approx. 0.15 VA
Frequency alternating current: 40 ... 1000 Hz
alternating voltage: 40 ... 10000 Hz
a
1
x a
2
l
1
x l
2
h
t
e
22...23.5
2)
17.5
1)
1) Individual contact protection
2) Full contact protection (22 mm for 48 x 48 front dimensions only)
3) ≥ 100 mA with attached matching transformer
Front Dim. in mm Nominal Dimensions, mm Cutout, mm Installation Depth, mm Terminals
a
1
x a
2
h
I
1
x I
2
t
t
1
e
≥ 100 mA
M4 M3
48 x 48 48 x 48 5 45
+0.6
x 45
+0.6
43.5 61.5
3
) 12.5 5.5
72 x 72 72 x 72 5 68
+0.7
x 68
+0.7
43.5 12.5 –
96 x 96 96 x 96 5 92
+0.8
x 92
+0.8
43.5 12.5 –
144 x 144 144 x 144 8 138
+1
x 138
+1
44.5 12.5 –
Commentaires sur ces manuels