H2/1 ORANGE/BLACK (-) accessory input (optional): Connect the H2/1 ORANGE/BLACK wire to the (-) acces-
sory output of the remote start system. This wire is located in the relay satellite ribbon harness on most DEI
remote start systems. The remote start accessory output will show ground as long as the remote start is activated,
except for a brief period when the system is cranking.
H2/2 BLUE/BLACK (-) status/second ignition input (optional): Connect this wire to the (-) status output or
(-) ignition output of the remote start system.
other plug-in harnesses
The status LED plugs into the white 2-pin socket. The program/record button plugs into the blue 2-pin socket of
the control module. There is also a phono-jack for the plug-in microphone.
system feature programming
The 516L has selectable dipswitch settings for programming the system’s features. The four dipswitches are
located underneath the unit’s removable door. To select a system feature setting, simply move the dipswitch in the
direction of the arrow for the ON setting, or in the opposite direction for the OFF setting:
DIPSWITCH/FEATURE NUMBER FEATURE ON SETTING OFF SETTING
1 LANGUAGE ENGLISH JAPANESE
2 MESSAGE TYPE VIPER GENERIC
3 SIREN MONITORING (BROWN WIRE) ON OFF
4 REMOTE START RUNNING MESSAGE REPEATING ONE TIME
dipswitch/feature settings