TM 11-6625-2611-12
CAUTION
Make sure ball plunger housing does not
scrape front panel when knob is rotated.
h. Insert flat-bladed screwdriver into hold in center
of knob and without disturbing position of knob, adjust
control until leading edge of first challenge pulse oc-
curs 0.2
µ sec after position referenced in d above.
i. Retighten setscrews.
j. Reconnect RF IN/OUT MAIN jack to LOW PWR
MEAS IN jack and check to see that first pulse is still
properly referenced at center of graticule then with
CHAL AUX MOD DLY control set at detent, check to
see that pulse of RF IN/OUT AUX jack is 0.2
µ sec
after pulse at RF IN/OUT MAIN jack.
5-9. Knob Replacement
All knobs are replaceable as part of organizational
maintenance. The following procedures are used for
replacing knobs.
a. Single Control Knobs (Except CHAL AUX MOD
DLY Knob).
(1) Loosen two setscrews and remove knob from
control shaft.
(2) Place replacement knob on shaft.
(3) Align pointer away from flat on control shaft
and tighten setscrew opposite pointer. Then tighten
other setscrew.
b. CHAL AUX MOD DLY knob replacement.
(1) Loosen two setscrews and remove knob and
ball plunger from control shaft.
(2) Install ball plunger into replacement knob.
(3) Install replacement knob on control shaft.
(4) Adjust control as described in paragraph 5-8.
c. Dual Knob Replacernent
(1) Loosen two setscrews of smaller knob.
(2) Remove smaller knob from control shaft.
(3) Loosen two setscrews of larger knob.
(4) Remove larger knob from control shaft.
(5) Install replacement for larger knob on control
shaft as described in a(2) and (3) above.
(6) Install replacement for smaller knob on con-
trol shaft as described in a (2) and (3) above.