Warn-Away response is triggered by:
Lesser or lighter vibrations or impacts (detected by the Stinger
Doubleguard shock sensor)
An optional Proximity Sensor (508D) triggered in the outer zone
Full Alarm response is triggered by:
Heavier impact to the vehicle (detected by the Stinger Double-
Guard shock sensor).
Opening the trunk or hood.
Opening a door: the Progressive Door Trigger feature will first
sound the Warn-Away response, followed immediately by Full
Alarm.
An optional sensor, such as an optional Proximity Sensor triggered
in the inner zone.
Any attempt to start the car: the Progressive Ignition Trigger will first
sound the Warn Away response, followed immediately by Full Alarm.
Paging Signals
If the Full Alarm response is triggered, the 2-way remote control will be
sent a paging signal by the in-car system.
Note:
Paging range varies with terrain and environmental condi-
tions.
While the alarm is triggering:
Press the
A U X
button on the remote. The siren will stop sounding and
disarm the alarm system.
High-Security Disarming
If you want the Full Alarm response to stop without unlocking the doors,
press the
A U X
button. The system will re-arm and the current alarm re-